Sign In | Join Free | My udpf.com
China Shanghai Shenglin M&E Technology Co., Ltd. logo
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Active Member

5 Years

Home > Clean Room Air Conditioning System >

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Shanghai Shenglin M&E Technology Co., Ltd.
Contact Now

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

  • 1
  • 2

Brand Name : Shenglin

Model Number : SL-ZKW Series

Certification : /

Place of Origin : China

MOQ : 1

Price : 500~4000USD/unit

Payment Terms : T/T, Western Union

Supply Ability : 100 Units Per Month

Delivery Time : 35~40days

Packaging Details : Plywood wooden box or pallet

Supply power : 220V / 50Hz.

Compressor type : No compressor

Air cooled or water cooled : Fresh air cooled

Feature : Has free cooling valve

Mounting : Wall mount

Fant type : EC fan

Contact Now

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Features:

1. The maximum air flow of at least 2000 m3 / h.
2. Minimum airflow is not more than 700 m3 / h.
3. Power supply 36-56 VDC (direct current).
4. Power consumption at the maximum air flow isn’t more than 300 W.
5. Power consumption at a minimum flow of air isn’t more than 20 W.
6. The power of the electric heater at least 1.5 kW, voltage 220V / 50Hz.

Technical Data:

Structure:

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

FCU should has:
1. Insulated body and the valve free cooling for inadmissibility through freezing at outdoor temperatures down to - 40 ° C by the cold climate zone, and up to - 20C in the performance for the warm climate zone;
2. Free cooling valve actuator with analog control, which allows smoothly change the position of the valve;
3. Air filter cassette-type, folding to replace the filter element, contamination control system;
4. Mosquito protection (pre-filter);
5. The prevention of access of outside air, controlled by a signal fire system;
6. Control system aerodynamic resistance cleaning filter (air flow pressure sensors at the inlet and outlet filters);
7. Electric heater, controlled by the controller (as an option).
8. FCU should has double filter which can protect BS from dust

Application:

Data centres or IT environments in colder climates.


Product Tags:

2000m3/H FCU AC Unit

      

2000m3/H Clean Room Air Conditioning System

      

FCU Clean Room Air Conditioning System

      
Best Wall Mounted Fan Coil FCU For Data Centres Free Cooling System wholesale

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Shenglin M&E Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)